Post Offer Free
PG Instruments Limited,  

Gold Index: 1496

You are here: home  > 1800 Grooves / mm Diffraction Grating, Atomic Absorption Spectrophotometer AA500F

1800 Grooves / mm Diffraction Grating, Atomic Absorption Spectrophotometer AA500F 

Place of Origin: Zhejiang, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: AA500F Atomic Absorption Sp...

 
Flame AA System AA500F 0.1, 0.2, 0.4, 1.0, 2.0nm Atomic Absorption Spectrophotometer

 

Flame AA System AA500F 0.1, 0.2, 0.4, 1.0, 2.0nm Atomic Absorption Spectrophotometer

 


The flame atomizer offers three flame options: Air/Acetylene is the standard configuration with the N2O/acetylene and Air/LPG as options.

 

Air/Acetylene
The Air/Acetylene flame uses a 100mm single slot burner for the standard configuration
The high sensitivity (Cu 2ppm>0.280Abs) is due to the efficiency of the fixed position glass nebulizer fitted as standard. An acid resistant replacement is available as an option.
The flame can be easily set from blue lean flame through stoichiometric to fuel rich by means of computer control


 

N2O/Acetylene
The N2O/Acetylene flame uses a 50mm single slot burner and is available as an optional extra.
This flame configuration is used to measure elements less prone to ionization such as Aluminum, Tin, Titanium, Calcium, Vanadium and Molybdenum.
Switching from Air/Acetylene to N2O/Acetylene to Flame Off is fully controlled by the AAWin Pro software


 

Air/Propane (LPG)
This flame uses a 3 slot burner and with the low pressure requirement it is also much safer to operate
Due to the low temperature of the flame it is ideal for analyzing alkali metals such as Potassium, Sodium and Lithium, especially when used in the emission mode.
Some remote areas of the world have difficulty obtaining Acetylene gas of a high enough purity to operate the flame correctly. LPG can give a real alternative and offer comparable results for most elements throughout the wavelength range.


 

Safety Features
Pressure monitoring for all gases
Burner identification
Flame sensor
Drain trap level sensor
Gas leak detector
Over pressure in premix
Safety cut off switch




Applications:

Agricultural
Clinical
Environmental
Food
Metal
Mining
Geological
Pertrochemical
Pharmaceutical

 

Specifications:

 

Spectrometer System

Wavelength range

190-900nm

Light source

Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)

Modulation 

Square wave pulse

Modulation frequency

100hz self reversal (SR) background, 400hz Deuterium Arc (D2) background

Monochromator 

Grating 

1800 grooves/mm diffraction grating

Blazed wavelength

250nm

Focus 

300nm

Bandwidth 

0.1, 0.2, 0.4, 1.0, 2.0, 5.0nm

Scan mode

Automatic

Photometric type

Single beam

Wavelength accuracy

+0.15nm

Wavelength resolution

0.2nm+0.02nm

Wavelength reproducibility

<0.05nm

Baseline stability

0.005A/30min

Stray light

≤0.12%T(220nm NaI, 340nm NaNO2)

Background correction

Deuterium Arc (D2) 1.0Abs, Self Reversal (SR) 3.0Abs

Flame Analysis

Flame types

Air/Acetylene, Nitrous Oxide/Acetylene, Air/Propane (LPG)

bigPhoto
 Mr. April Cao

Tel: 86-10-69910653
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

PG Instruments Limited, [China (Mainland)]


Business Type:Manufacturer
City: Beijing
Province/State: Beijing
Country/Region: China (Mainland)

You May Like:

Product (28)